In collaboration with Nasa Glenn Research Center, CISSOID components have shown an operational temperature range from -195°C to +300°C.
The voltage regulator (CHT-LDO-033-TO3) and the Voltage reference (CHT-BG3M-025-TO39) have been tested by GRS from -195°C to 100°C and by CISSOID from 25°C to 300°C ambiant temperature. Both circuits are operational in this very large temperature range. The voltage reference shows a global precision of 5% on the complete temperature range. The voltage regulator present a global precision of 6%.

Both circuit can stop and start at extreme low and high temperature.

The 555 Time (CHT-555-TO8) has also been tested at low temperature by GRS and is under test at high temperature by CISSOID.

Some temperature cycling have been made but are not significant.